Percona Alerting issues

No Alert rule templates tab on the Alerting page

Percona Alerting option isn’t active.

  1. Go to PMM Configuration > Settings > Advanced Settings.
  2. Enable Alerting.

Custom alert rule templates not migrated to Percona Alerting

If you have used Integrated Alerting in previous PMM versions, and had custom templates under /srv/ia/templates, make sure to transfer them to /srv/alerting/templates. PMM is no longer sourcing templates from the ia folder, since we have deprecated Integrated Alerting with the 2.31 release.

Unreachable external IP addresses

If you get an email or page from your system that the IP is not reachable from outside my organization, do the following:

To configure your PMM Server’s Public Address, select Configuration SettingsAdvanced Settings, and supply an address to use in your alert notifications.

Alert Rule Templates are disabled

Built-In alerts are not editable, but you can copy them and edit the copies. (In PMM 2.14.0 and above).

If you create a custom alert rule template, you will have access to edit.